| TOOL STEELS |
| D,S,M,O,H,P Series |
Hi Pressure |
| Rc |
SFM |
|
| 17-22 |
250 |
| 22-27 |
200 |
| 27-32 |
150 |
| 32-37 |
100 |
| |
| ALLOY STEELS |
| 4000, 5000, 8000 Series |
|
| Rc |
SFM |
|
| 17-22 |
300 |
| 22-27 |
250 |
| 27-32 |
200 |
| 32-37 |
150 |
| 37-42 |
100 |
| |
| Low to Med. CARBON STEEL |
| C1010-1550 |
| Rc |
SFM |
|
| 12-17 |
400 |
| 17-22 |
350 |
| 22-27 |
300 |
| 27-32 |
250 |
| 32-37 |
200 |
| 37-42 |
150 |
| |
| STAINLESS STEEL* 300
Series |
| 300 Series & PH |
| Rc |
SFM |
|
| 12-17 |
230 |
| 17-22 |
200 |
| 22-27 |
170 |
| 27-32 |
140 |
| 32-37 |
110 |
| 37-42 |
80 |
| Free Machining |
+ 30% |
| |
| STAINLESS STEEL *
400 Series |
| 400 Series |
| Rc |
SFM |
|
| 12-17 |
280 |
| 17-22 |
240 |
| 22-27 |
200 |
| 27-32 |
160 |
| 32-37 |
120 |
| 37-42 |
80 |
| Free Machining |
+ 30% |
| |
| CAST IRON |
| Grey |
| Rc |
SFM |
|
| 12-17 |
400 |
| 17-22 |
350 |
| 22-27 |
300 |
| 27-32 |
250 |
| With Free Carbides |
-50% |
| Ni-Resist |
-60% |
| |
| CAST IRON |
| Ductile, Nodular |
| Rc |
SFM |
|
| 12-17 |
300 |
| 17-22 |
250 |
| 22-27 |
200 |
| 27-32 |
150 |
| 32-37 |
100 |
| Ductile, Ni-Resist |
-50% |
| |
| TITANIUM* |
| 6A1 4V, Some Others |
| Rc |
SFM |
|
| 12-17 |
260 |
| 17-22 |
220 |
| 22-27 |
180 |
| 27-32 |
140 |
| 32-37 |
100 |
| 37-42 |
60 |
| |
| HIGH TEMP. ALLOYS* |
| Nickel Based |
|
| Rc |
SFM |
|
| 12-22 |
120 |
| 22-32 |
90 |
| 32-42 |
60 |
| Cobalt Base |
-40% |
| Iron Base |
+20% |
| |
| COPPER ALLOYS* |
| Berryllium, Ni-Based |
|
| Rc |
SFM |
|
| 12-22 |
200 |
| 22-32 |
130 |
| 32-37 |
60 |
| |
| SOFT ALLOYS Non Ferrous |
| Aluminum, Copper, Free Brass, Magnesium |
500 - 600 SFM |
| All Conditions |
|
|
- Consult Sterling Gun Drills to verify application requirements.
- High SFM will cause vibration and/or harmonics with long gun drills. Reduce RPM or ensure adequate supports are in place or use an intermediate length gun drill.
- Minimum oil/coolant pressure is 35% of the PSI values on page 2. If at minimum, reduce SFM by 35%.
- Applications suitable for our Spraymist System, reduce SFM by 35% at same feed rate listed.
- Water soluble coolant must be oil based, high “EP” at 10-12% concentration, NO SYNTHETICS!
|
|